Route off-line compressor gas to fuel with the following options. |
| Text: |
Methane Recovery - Option 2: "Route off-line compressor gas to fuel
â—† Connect blowdown vent to fuel gas system
â—† Off-line compressor equalizes to fuel gas pressure (100 to 150 pounds per square inch)
â—† Eliminates methane vents
â—† Seal leak higher by 0.125 Mcf/hr
â—† Reduces fugitive methane losses by 1.275 Mcf/hr (91%)" |